Atmospheric Vortex Engine Thermodynamics Basis
29.75M
Категория: ПромышленностьПромышленность

Atmospheric Vortex Engine Thermodynamics Basis

1. Atmospheric Vortex Engine Thermodynamics Basis

Louis Michaud, P. Eng.
Chairman, Chief Technical Officer
AVEtec Energy Corporation
http://vortexengine.ca

2.

3.

4.

5.

6.

7.

Atmospheric work production process
Energy conservation in an open system

8.

A hurricane viewed as a Carnot cycle
Efficiency
n = 1 – Tc / Th = 1 – 200/300 = 33%
Source Divine Wind by Kerry Emanuel

9.

10.

11.

Reversible and Irreversible Expansion
Latch #2
Piston
Latch #1
Valve
#1
Base pressure
100 kPa
Rising Air
Column
Ambient Air
Column
Automat
in vacuum
Valve
#2
Cylinder
and Piston
Base Pressure
95 kPa
Constrained reversible expansion - Work is produced - No Latch
1. Start with piston at bottom of the cylinder, open valve #1,
2. Automat raises piston and let 1 kg of air at 100 kPa in cylinder,
3. Close valve #1,
4. Automat raises piston until cylinder pressure decreases to 95 kPa,
5. Open valve #2,
6. Automat pushes piston to the bottom of the cylinder.
The air temperature decreases.
Unconstrained irreversible expansion - No work is produced - Two Latches
1-3. As above except after step 3. set latch #1 and #2,
set latch #2 so that the final pressure is 95 kPa,
4. Automat lets go of the piston,
5. Let go latch #1, piston snaps against latch #2 without doing any work,
6. Automat pushes piston to the bottom of the cylinder.
The air temperature does not decrease.

12.

13.

14.

Gravity Power Cycle

15.

Brayton gas-turbine power cycle

16.

17.

Irreversible Gravity Cycle

18.

2

19.

20.

Work Calculation
Upflow in a Tube
W = Dh - Dgz

21.

Case 1: S7 = 3 kg/s

22.

Case 2: S7 = 500 kg/s

23.

Heat flux from rain and sea cooling
From rain
Qv = Lv m d2 (p/4)
for: m = 10 mm/hr (0.0028 kg/s m2)
d = 300 km
Qv = 491 TW
From sea cooling
Qt = Cw DT w d v
for: DT = 2.5°C, d = 100 m
w = 100 km, v = 5 m/s
Qt = 524 TW
Per unit spray production area
Qe = Q / A
for: Q = 500 TW, A = 2500 km2,
L = 50 km, w = 50 km
Qe = 200,000 W/m2
Per unit spray deposition area
Qa = 40,000 W/m2
• 2500 km2 green circle – Spray production area.
•12,500 km2 red circle – Spray deposition area.
Figure: Black et al. BAMS March 2007

24.

Hurricane Isabel effect on sea surface temperature as observed from satellite

25.

26.

• The AVE replaces the
physical chimney with
centrifugal force in a
vortex.
• The AVE eliminates the
solar collector by using
waste heat or natural low
temperature heat sources.

27.

Conditions:
Collector Efficiency 31 %
Turbine Efficiency 80 %
Insolation 1000 W/m2
Dia. Chimney 10 m
Dia. Collector 244 m
Total Insolation 37,700 kW
Conditions:
Pb 100 kPa
Tb ambient 30 °C
Tt ambient 28 °C
Tb chimney 47 °C
z 200 m
Velocity 8 m/s
Flow 680 kg/s
Resulting efficiency:
Ideal 0.64 % (Carnot)
Actual 0.35 %
Overall 0.11 %
Ideal Work
75 kW
Exit vel. k.e.
22 kW
Friction losses
4 kW
Turbine Loses
8 kW
(110 J/kg)
Work 41 kW
Heat input
11,680 kW
Manzanares Solar Chimney – Energy budget
(Based on actual operating conditions)

28.

Lambton College prototype vortex

29.

30.

31.

Vortex Engine
Terawatt Challenge Miracles
1. Can use low temperature heat source
2. No need for a heat collector
3. No need for energy storage
4. Spray can provide high heat transfer
5. No need for a physical chimney
6. Low friction and exit losses
7. Efficiency increases with height
8. No mechanical compressor
9. Greenhouse gasses help
10.Work is transferred to turbine located at grade