Похожие презентации:
Lecture 8 ПДК
1.
LECTURE 8Wood and Plywood
Arches
Structural systems, design principles, connections,
assembly considerations
Prepared by: S. Niyetbay
2.
Lecture Objectives and Key TopicsUnderstand how an arch carries loads and how it differs
from a beam.
Examine the main types of wood and plywood arches, their
efficient spans, and applications.
Explain the geometry, support reactions, and internal
forces of a three-hinged arch.
Learn the basic principles of checking arch sections for
strength and stability.
Discuss transportation, assembly, and connection details
for large-span arches.
Key idea: an arch transfers loads
to its supports through axial
compression as well as bending.
Arch axis
Tie rod or support reaction
9-ДӘРІС
Ағаш және фанера аркалары
2
3.
How Does an Arch Work?Horizontal support reaction reduces the bending moment
An arch is a load-bearing member with a curved axis.
Under vertical loading, both vertical and horizontal
reactions develop at the supports.
The horizontal reaction reduces bending moments in
arch sections. Consequently, most of the material works
in compression.
If the supports cannot resist the horizontal force, they
are connected by a tie rod. The tie works in tension and
carries the arch thrust.
An arch becomes more efficient as its axis approaches
the line of thrust produced by the loads.
Vertical load
↓ ↓ ↓ ↓ ↓
H
H
The material works mainly in
compression, making timber
arches suitable for covering large
spans.
9-ДӘРІС
Ағаш және фанера аркалары
3
4.
Main Types of Timber ArchesShape, cross-section, and connections are selected according to span
Solid glued-laminated arches can be factoryproduced in curved shapes. They offer high
geometric accuracy and an attractive appearance.
Arches assembled from boards or timber
members are joined by mechanical fasteners.
Such solutions are used for small and medium
spans.
Arches may be solid or built-up, two-hinged or
three-hinged. The three-hinged system is
convenient for erection and thermal movements.
Plywood-web and box sections save material and
increase sectional stiffness.
Arch configurations: glued-laminated, solid-timber, and board-built members
9-ДӘРІС
Ағаш және фанера аркалары
4
5.
Selecting the Structural SystemCondition
Recommended Solution
Small or medium span
Arch made of boards, timber beams, or solid glued-laminated
sections
Large span
Box-section, lattice, or built-up cross-sections; prefabricated
factory-made units
Supports cannot resist
horizontal thrust
Tied arch
Temperature effects and
support settlement are
significant
Three-hinged arch system
Transportation dimensions
are limited
Half-arches or prefabricated units with assembly joints
Selection must consider not only the design span but also the building function, architectural requirements,
moisture conditions, fire safety, and erection possibilities.
9-ДӘРІС
Ағаш және фанера аркалары
5
6.
Arch Connections and Force TransferConnections must ensure a continuous load path
The support connection transfers axial
compression to the foundation or column.
Steel plates and anchors limit local
crushing of the timber.
The crown hinge connects the two halfarches. It allows the rotation assumed in
the structural model and simplifies
erection.
Members in a built-up section act together
through bolts, shear keys, toothed plates,
or adhesive bonding.
When detailing fasteners, check splitting
along the grain, bearing stresses, and
weakening around bolt holes.
Figure 7.1. Structural details of arch connections
9-ДӘРІС
Ағаш және фанера аркалары
6
7.
Geometry of a Three-Hinged ArchThe main dimensions are span l, rise f,
and curvature of the arch axis. As the
rise increases, the horizontal support
reaction generally decreases.
For analysis, the arch axis is divided into
several sections. Coordinates x and y
and tangent inclination angle φ are
determined for each section.
The arch axis may be modeled as a
circular arc, parabola, or another design
curve.
Even when the load pattern is
symmetric, asymmetric cases such as
snow accumulation on one side must
also be considered.
Figure 7.2. Geometry of the arch axis and design parameters
9-ДӘРІС
Ағаш және фанера аркалары
7
8.
Determining Support ReactionsA three-hinged arch is statically determinate
H = M₀C / f
where M₀C is the moment at the crown section of a
simply supported beam under the same loading; f is the
arch rise.
If the arch rise is too small, H increases, placing
demands on the supports and tie.
9-ДӘРІС
Ағаш және фанера аркалары
First, vertical support reactions are obtained
from equilibrium equations, as for a simply
supported beam.
Because the bending moment at the crown
hinge is zero, this condition allows the
horizontal reaction H to be calculated.
Under a fully symmetric load, the reactions
are also symmetric. Under one-sided
loading, the left and right support reactions
differ.
In a tied arch, the tie rather than the
supports carries force H. The tie must
therefore be checked for tension and its
connections for pull-out.
8
9.
Internal Forces in Arch SectionsM = M₀ − H·y
N = Q₀·sinφ + H·cosφ
Q = Q₀·cosφ − H·sinφ
Design load combinations: dead load, full snow
load, one-sided snow load, and erection
conditions where applicable.
9-ДӘРІС
Ағаш және фанера аркалары
M₀ and Q₀ are determined for a simply
supported beam with the same span as the
arch.
The term H·y reduces the beam moment.
Therefore, the bending moment in an arch
is lower than in a beam of the same span.
The axial force N in an arch is generally
compressive. It affects both sectional
strength and overall stability.
The shear force Q may be important near
supports and at locations where loading
changes abruptly.
9
10.
Checking Cross-Section StrengthCompression and bending act simultaneously
The arch section is designed for axial compressive force
N and bending moment M. Their combined stress effect
is compared with the relevant design resistances.
Weakened areas, bolt holes, and erection joints are
assessed using the actual net section.
Curved glued-laminated members may develop tension
perpendicular to the grain. This effect increases when
the radius of curvature is too small.
Bearing perpendicular to the grain is checked separately
at supports and connections.
Verification
sequence
1 Design N, M, Q
2 Net cross-section
3 Combined stresses
4 Connections and
bearing
Design resistance depends on timber
species, moisture conditions, load
duration, and service conditions.
9-ДӘРІС
Ағаш және фанера аркалары
10
11.
Arch StabilityCheck overall and out-of-plane stability
Because an arch is a curved compression member, its
effective length and slenderness are crucial.
In-plane stability depends on the arch shape, support
conditions, and load position.
Out-of-plane stability is provided by roof members,
transverse bracing, and the longitudinal bracing system.
Loads applied to the upper edge and eccentricity
produce additional moments. These effects are included
in the structural model.
As the spacing between braces increases, the unbraced
length grows and the stability reserve decreases.
transverse bracing
An arch does not work in isolation.
The building’s spatial bracing
system ensures its stability.
9-ДӘРІС
Ағаш және фанера аркалары
11
12.
Erection Joints and Built-Up ArchesTransporting a large arch as a single
member is difficult. Therefore, it is
manufactured as two half-arches or several
erection segments.
Erection joints must reliably transfer axial
compression, shear, and, where necessary,
bending moment.
Steel cover plates, bolts, internal plates, and
bearing components work together with the
timber members.
Joint stiffness must match the structural
model. A connection modeled as a hinge
must not unintentionally restrain bending.
During erection, temporary supports and
braces remain in place until the arch is
integrated into the complete spatial system.
Figure 7.4. Erection joints in large-span arches
9-ДӘРІС
Ағаш және фанера аркалары
12
13.
Fasteners in Built-Up Timber MembersFor individual boards and members of a
built-up section to act as one element,
shear forces must be transferred through
fasteners.
Fastener spacing is determined by the
design shear flow. Spacing is reduced in
regions of higher force.
Around bolts and shear keys, check
timber bearing, fastener bending, and the
risk of splitting along the grain.
Symmetric fastener arrangements reduce
section twisting and local eccentricity.
Figure 6.6. Arrangement of fasteners in built-up beams and members
This principle also applies to the design of built-up arch
sections and erection joints.
9-ДӘРІС
Ағаш және фанера аркалары
13
14.
Requirements for Design and ErectionMoisture protection
Fire safety
Prevent roof leakage, detail joints to avoid water
accumulation, and provide ventilation.
Account for the charred layer of the section; use
protective cladding or fire-retardant treatments.
Transportation
Erection
Segment dimensions must comply with vehicle
limits, lifting points, and temporary strength
requirements.
Provide temporary restraints, check geometry, and
install permanent bracing in stages.
A good design is more than calculations: material protection, correct connections, and proper erection
sequence determine long-term structural performance.
9-ДӘРІС
Ағаш және фанера аркалары
14
15.
ConclusionsTimber arches can cover large spans with relatively little
material because a significant part of the load is transferred
through axial compression.
Efficient arch behavior depends on geometry, rise, support
conditions, and load pattern.
Design involves determining support reactions and internal
forces M, N, and Q, followed by checks of sectional strength
and stability.
Connections and erection joints must reliably transfer forces,
while spatial bracing must ensure out-of-plane stability.
Moisture protection, fire safety, and proper erection are
essential for the long and safe service life of timber arches.
9-ДӘРІС
Ағаш және фанера аркалары
Review question: How does the
horizontal support reaction
change when the arch rise
decreases?
15