Folie 1
Folie 2
Folie 3
Folie 4
Folie 5
Folie 6
Folie 7
Folie 8
Folie 9
Folie 10
Folie 11
Folie 12
Folie 13
Folie 14
Folie 15
Folie 16
Folie 17
Folie 18
Folie 19
Folie 20
Folie 21
Folie 22
Folie 23
Folie 24
Folie 25
Folie 26
Folie 27
Folie 28
Folie 29
Folie 30
Folie 31
Folie 32
Folie 33
Folie 34
Folie 35
Folie 36
Folie 37
Folie 38
Folie 39
Folie 40
Folie 41
Folie 42
Folie 43
Folie 44
Folie 45
Folie 46
Folie 47
Folie 48
Folie 49
Folie 50
Folie 51
Folie 52
Folie 53
Folie 54
Folie 55
Folie 56
Folie 57
Folie 58
Folie 59
Folie 60
Folie 61
4.27M
Категории: ФизикаФизика ХимияХимия

Mass spectrometry

1. Folie 1

Mass Spectrometry
Frequently Asked Questions
Dr. Markus Wunderlin, Seminar 07.07.2004

2. Folie 2

Overview
Mass Spectrometry in a Nutshell - Facts and Basics
Mass Resolution and Mass Accuracy
Fragmentation – Dissozation – Adduct Formation
Impurities - Contamination - Artefacts
FTICR-MS: The „Ferrari Age“ Of MS

3. Folie 3

Facts and Basics
Mass Spectrometry
A technique for measuring and analyzing molecules, that
involves introducing enough energy into a (neutral)
target molecule to cause its ionization and
disintegration. The resulting primary ions and their
fragments are then analyzed, based on their mass/
charge ratios, to produce a "molecular fingerprint."

4. Folie 4

Facts and Basics
Difference Between Spectrometric Methods:
Ionization implies a chemical process induced by
physical methods. The sample is consumed during the
measurement. Their is no defined stimulation of
molecular energy levels through interaction with
electromagentic radiation, where you can get the sample
back without modification.

5. Folie 5

Structural Information by MS
MW determination
nominal
accurate (elemental composition)
Isotope pattern
High resolution
Fragmentation
Fragmentation rules
Libraries („fitting“)
MS/MS (or MSn)

6. Folie 6

Components Of A Mass Spectrometer
Ionisation
Ion Source
Ion Separation
Mass Analyser
Ion Detection
Detector
Electron Ionisation (EI)
Quadrupole
Chemical Ionisation (CI)
Magnetic Sector Field
Multichannel plate
Electric Sector Field
Faraday Cup
Fast Atom Bombardment (FAB)
Electrospray Ionisation (ESI)
Matrix-Assisted Laserdesorption/
Ionisation (MALDI)
Time-Of-Flight (TOF)
Ion Trap
Electron Multiplier

7. Folie 7

Sektion MS: Mass Spectrometers
EI
CI
ESI
APCI
Bruker
Reflex III
+
Finnigan
SSQ7000
+
+
Finnigan
TSQ700
(+)
(+)
Finnigan
TSQ7000
MALDI FAB
MS/MS
PSD
+
(+)
+
+
Inlet
+
GC, SP, DEP
GC, SP, DEP
Nano-ESI
Status

8. Folie 8

Sektion MS: Info & Data
Homepage „Sektion Massenspektrometrie“
http://www.uni-ulm.de/uni/fak/natwis/oc2/massenspektrometrie/index.htm
FTP-Server
for data collection (MALDI, EI, CI, FAB) like the NMR-service
Server: 134.60.63.96
Username:OC2
PW:Maldi

9. Folie 9

MS Software
Software for MALDI data analysis
Bruker Data Analysis 1.6d
Software for EI, CI and FAB data analysis
ACD Labs MS Processor

10. Folie 10

What type of analysis is needed ?
Ionization methods: MALDI, EI, CI, (FAB), (ESI)
– I will select the ionization method unless
• you have previous success with a method
• duplicating literature methods
- Analyses are low resolution
• confirms presence of analyte
• for high mass compounds (m/w >10000) I try to obtain the best
resolution possible
• for high mass accuracy internal calibration (standard: external
calibration)

11. Folie 11

What type of analysis is needed ?
Which MS method is best for the compound I
want to analyze ?
Molecular weigth?
Solvent & solubility?
Purity?
Reactivity?
Would it distill or sublime under HiVac ?
One compound or mixture?
Acidic? Basic?
Ionic?

12. Folie 12

Ionization Methods
Neutral species Charged species
• Removal/addition of electron(s)
– M + e- (M+.)* + 2e• electron ionization
• Removal/addition of proton(s)
– M + (Matrix)-H MH+ + (Matrix)• chemical ionization (CI)
• atmospheric pressure CI (APCI)
• fast atom bombardment (FAB)
• electrospray ionization (ESI)
• matrix assisted laser desorption/ionization (MALDI)

13. Folie 13

Matrix Assisted Laser Desorption

14. Folie 14

Matrix Assisted Laser Desorption
TOF Parameters
Simple, cheap (in theory), robust, sensitive.
A good modern TOF should give:
English     Русский Правила