Thesis proposal
Topic of the thesis
Preliminary Result 1: Study of the effects of target spectrum corruption due to light fluence
Preliminary Result 2: Study of the effects of performance contamination due to targets occupying large areas
Work in progress: Diagonal loading can enhance the detection performance when the target is occupying large areas
119.02K

Thesis proposal. AMF has shown to improve the sensitivity of molecular MSOT

1. Thesis proposal

Andrii Kravtsiv

2. Topic of the thesis

• AMF has shown to improve the sensitivity of molecular MSOT
imaging in a number of applications such as cell imaging
• However its applications is not robust in cases
– where the target occupies a large area in the image
– where the spectrum of the target agent is significantly corrupted by light
fluence
• This thesis will be devoted in studying the performance of AMF
under such challenging conditions and developing solutions for
mitigating such effects and ensuring global robust performance.

3. Preliminary Result 1: Study of the effects of target spectrum corruption due to light fluence

0.7
Sensitivity limits of the different algorithmic approaches
AMF
AMF coloring
Sensitivity limit: Simulated    a (cm­1)
0.6
0.5
0.4
0.3
0.2
0.1

Brain ICG
Brain ink
Kidney ICG
Kidney ink
 
• The effect of sensitiivty decrease
due to the corruption of the
target spectrum is studied
• While this effect is minimum
when agents with sharp
spectrum are considered (e.g.
ICG), spectral corruption can be
important when agents such as
ink are utilized.

4. Preliminary Result 2: Study of the effects of performance contamination due to targets occupying large areas


20
40
60
80
100
120
140
160
180
20
40
60
80
100
120
140
160
20
20
40
40
60
60
80
80
100
100
120
120
140
140
160
160
180
180
200
200
20
40
60
80
100
120
140
160
180
200
20
20
40
40
60
60
80
80
100
100
120
120
140
140
160
200
3.5
3
20
40
60
80
100
120
140
160
180
200
40
60
80
100
120
140
160
180
200 200
2
1.5
1
0.5
­0.5
180
20
2.5
0
160
180
200
180
Sensitivity limit: Simulated    a (cm­1)
200
The effect of sensitiivty decrease as a function of
the area of the molecular target is studied
Targets are implanted in gradually decreasing
areas and the sensitivity is calculated
We observe a significant degradation of
algorithmic performance as a function of the
target area.
20
40
60
80
100
120
140
160
180
200
1024 pix
512 pix
256 pix
128 pix
Area occupied by target
64 pix

5. Work in progress: Diagonal loading can enhance the detection performance when the target is occupying large areas

4
2.5
x 10
 
mouse3
prior background ­ mouse4
2
prior background ­ mouse2
Signal­to­Clutter Ratio
contaminated background mouse3
diagonal loading, betha=10­8
diagonal loading, betha=10­9
1.5
diagonal loading, betha=10­10
1
0.5

0
0.2
0.4
0.6
0.8
1
Abundance
1.2
1.4
1.6
1.8
­5
x 10

6.

20
20
40
40
60
60
80
80
100
100
120
120
140
140
160
160
180
180
200
20
40
60
80
100
120
140
With diagonal loading
160
180
200
200
20
40
60
80
100
120
140
160
180
200
Without diagonal loading
Performance of AMF filter with and without diagonal loading in covariance matrix